RT Series 5/6/8/10/15/20 kVA

RT Series 5/6/8/10 kVA Single Phase UPS, 15/20 kVA Three Phase UPS

A total solution for reliable power with high availability and performance

The Amplon RT Series 5-20kVA is an online double-conversion UPS that provides best-in-class designs in compact 2U size, high power density, system efficiency, and versatile configurations to fulfill customers' requirements. Unity output power factor maximizes capacity for more critical loads, while outstanding energy savings can be achieved based on the AC-AC efficiency of up to 96.5% and 99% in ECO mode. In addition, RT Series 5-20kVA UPS is the first in the market that offers standard Li-ion external battery cabinets, which deliver better power density and sustainability. Along with the parallel capacity of up to four units, the new series is the ideal small power UPS for mission-critical applications, such as servers, data centers, telecommunications, and manufacturing.


Downloads Request a Quote Subscribe Newsletter

Product Introduction

Features & Benefits

Availability & Flexibility

  • True online double-conversion topology and zero transfer time to battery provides 24/7 full-time protection
  • Wide input voltage range allows the UPS to operate in harsh electrical environments and extends battery life
  • AC-start function allows the UPS to be switched on without connecting to a battery
  • Programmable load bank disconnects non-critical loads when a blackout occurs and reserves more battery power for critical loads
  • Up to four units parallel capacity allows redundancy and load expansion
  • Hot swappable batteries ensure continuous operation even when batteries are being replaced
  • VRLA and Li-ion External Battery Cabinet (EBC) are available for scalable runtime
  • Extended Runtime models support flexible battery quantity for battery investment optimization. And when one battery fails, it could be removed without replacing the entire battery string, reducing maintenance cost and efforts
  • The Power Distribution Box (PDB) and Maintenance Bypass Breaker (MBB), which are default to RT 5-10kVA Standard Runtime models, enable simple configuration
  • The Maintenance Bypass Breaker (MBB) is optional for easy UPS replacement without powering down critical systems
  • The rRPP (Rack Remote Power Panel), which can be integrated with standard server racks, simplifies power output distribution and power monitoring
  • Common battery configuration is supported in RT 15/20kVA parallel mode to save installation space and additional battery costs
 

Efficiency & Reliability

  • Unity output power factor guarantees no de-rating with loads and provides permanent 100% kW
  • Best-in-class AC-AC efficiency of up to 96.5% and 99% in ECO mode lowers energy costs
  • Automatic fan speed control maximizes system efficiency and significantly reduces audible noise and prolongs battery life
  • Fan failure detection sends early warnings to facilitate predictive maintenance of UPS
 

Manageability

  • Intelligent battery management to extend battery life and maximize battery performance. The battery aging detection monitors battery status for predictive maintenance, and the 3-stage charging mechanism keeps the battery from continuous float charging during the intermission stage to prolong battery life
  • Excellent local management through a user-friendly graphical and multi-lingual LCD display
  • Various types of communication interfaces, including USB, RS-232, and RS-485 ports, mini slot, REPO/ROO for remote management, and in-built dry contacts for monitoring and notification of system operation conditions
  • UPS management software such as ShutdownAgent and InfraSuite Device Manager allow users to monitor UPS status and protect critical devices
Applications

UPS RT series applications

Specifications
  1. Model
  2. RT-5K: Power Rating - 5kVA / 5kW
    RT-6K: Power Rating - 6kVA / 6kW
    RT-8K: Power Rating - 8kVA / 8kW
    RT-10K: Power Rating - 10kVA / 10kW
    RT-15K3P: Power Rating - 15kVA / 15kW
    RT-20K3P: Power Rating - 20kVA / 20kW

  3. Input
  4. Voltage Range - RT-5K/6K/8K/10K:
    100~280Vac (Single phase, 2-wire + G)
    100~175Vac with linear de-rating 50~100%
  5. Voltage Range - RT-15K3P/20K3P:
    138~485Vac (Three phase, 4-wire + G)
    138~305Vac with linear de-rating 40~100%
  6. Frequency: 40~70Hz
  7. Power Factor: > 0.99 (full load)
  8. iTHD: < 3%
  9. Input connection - RT-5K/6K/8K/10K: Input terminal x 1
  10. Input connection - RT-15K3P/20K3P: Input terminal x 1, Bypass Input terminal x 1

  11. Output
  12. Power Factor: Unity
  13. Voltage - RT-5K/6K/8K/10K: 200/208/220/230/240Vac (Single phase)
  14. Voltage - RT-15K3P/20K3P: 380/400/415Vac (Three phase), or 220/230/240Vac (Single phase)
  15. Frequency: 50/60Hz ±0.05Hz
  16. Voltage Harmonic Distortion: ≤ 2% (linear load)
  17. Overload Capability - RT-5K/6K/8K/10K:
    ≤ 105%: continuous
    106~125%, 5 minutes
    126~150%, 1 minute
    > 150%: 500ms
  18. Overload Capability - RT-15k3P/20K3P:
    ≤ 105%: continuous
    106~125%: 2 minutes
    126~150%: 30 seconds
    > 150%: 200ms

  19. Receptacle
  20. Standard Runtime Model
    RT-5K/6K: C13 x 6, C19 x 2, Terminal x 1, Load bank: C19 x 1
    RT-8K/10K: C13 x 6, C19 x 4, Terminal x 1, Load bank: C19 x 1
  21. Extended Runtime Model
    RT-5K/6K/8K/10K: Terminal x 1, Load bank: Terminal x 1
    RT-15K3P/20K3P: Terminal x 1

  22. Efficiency
  23. AC-AC
    RT-5K/6K/8K/10K: Up to 95.5%
    RT-15K3P/20K3P: Up to 96.5%
  24. ECO Mode: Up to 99%

  25. Battery Voltage
  26. Standard Runtime Model
    RT-5K/6K: 192Vdc
    RT-8K/10K: 240Vdc
  27. Extended Runtime Model
    RT-15K3P/20K3P: ±144Vdc*, ±192~±264Vdc

  28. Charger Current
  29. Standard Runtime Model
    RT-5K/6K: 1A (default)
    RT-8K/10K: 1.5A (default)
    RT-15K3P/20K3P: Up to 8A
  30. Extended Runtime Model: Up to 8A

  31. Typical Backup Time (Run Time Table)
  32. Standard Runtime Model - 75% load
    RT-5K: 7.5min
    RT-6K: 5.5min
    RT-8K: 9min
    RT-10K: 6min
    RT-15K3P/20K3P: Depending on different configurations required by customers
  33. Standard Runtime Model - Full load
    RT-5K: 5min
    RT-6K: 3min
    RT-8K: 5min
    RT-10K: 3.5min
  34. Extended Runtime Model : Depending on different configurations required by customers

  35. Audible Noise
    RT-5/K6K: 48dB
    RT-8K/10K: 50dB
    RT-15K3P/20K3P: 54dB

  36. Display: Graphical and multi-lingual LCD

  37. Communication Interfaces: MINI Slot x 1, Parallel Port** x 2, USB Port x 1, RS232 Port*** x 1, RS485 Port x 1, REPO/ROO Port x 1, Dry Contact x 4

  38. Dimensions (W x D x H)
  39. Standard Runtime Model
    RT-5K/6K: 440 x 665 x 176mm
    RT-8K/10K: 440 x 750 x 218mm
  40. Extended Runtime Model
    RT-5K/6K: 440 x 430 x 88.2mm
    RT-8K/10K: 440 x 565 x 88.2mm
    RT-15K3P/20K3P: 440 x 760 x 88.2mm

  41. Weight
  42. Standard Runtime Model
    RT-5K/6K: 54kg
    RT-8K/10K: 85.5kg
  43. Extended Runtime Model
    RT-5K/6K: 10.9kg
    RT-8K/10K: 15.2kg
    RT-15K3P/20K3P: 22.5kg

  44. Environment
  45. Operating Temperature: 0~55°C****
  46. Relative Humidity: 5~95% (non-condensing)

  47. * De-rating to 70% load
    ** Only applicable to RT 5-10kVA Extended Runtime Model and RT 15/20kVA
    *** Not applicable to RT 15/20kVA
    **** When the operating temperature is at 40~55°C, the UPS will be de-rated to 75% of its capacity

    All specifications are subject to change without prior notice.
     
Runtime Table
  1. Standard Model
  2. Power Rating Internal Battery External Battery Cabinet Quantity Run time at different load (mins)
    25% 50% 75% 100%
    5 kVA - 200/208V
    (UPS502R2RT0B0B8)
    Yes 0 35.6 15.6 8.9 5.6
    1 68.0 31.0 19.0 13.0
    2 106.0 51.0 32.0 22.6
    3 145.5 71.5 45.5 32.5
    4 185.0 91.5 59.0 42.5
    5 kVA - 220/230/240V
    (UPS502R2RT0B035)
    Yes 0 35.2 15.2 7.8 5.1
    1 61.0 27.0 16.5 11.0
    2 96.0 45.5 28.0 19.5
    3 131.0 63.5 40.0 28.5
    4 166.5 82.0 52.5 37.5
    6 kVA Yes 0 24.3 9.6 5.6 3.1
    1 50.0 22.0 13.0 8.5
    2 79.5 37.0 22.5 15.5
    3 109.0 52.0 32.5 22.5
    4 137.0 67.0 42.5 30.0
    8 kVA Yes 0 36.3 15.6 9.3 5.1
    1 71.0 27.0 14.5 9.6
    2 119.0 49.5 27.5 17.5
    3 167.5 73.5 42.5 27.5
    4 217.0 98.0 58.0 39.0
    10 kVA Yes 0 30.2 11.9 6.2 3.7
    1 53.0 19.4 10.5 7.4
    2 91.0 36.0 19.5 12.5
    3 130.0 54.8 30.5 19.5
    4 170.0 74.0 42.5 28.0
  3.  
  4. Extended Model
  5. Power Rating External Battery Cabinet P/N External Battery Cabinet (EBC) Quantity Run time at different load (mins)
    25% 50% 75% 100%
    5 kVA BBU161B107035 1 35.2 15.2 7.8 5.1
    2 61.0 27.0 16.5 11.0
    3 96.0 45.5 28.0 19.5
    4 131.0 63.5 40.0 28.5
    BBU201B109035 1 50.0 18.5 10.3 7.3
    2 123.5 53.2 30.0 19.3
    3 199.5 91.0 54.2 36.0
    4 276.4 130.0 79.5 54.5
    6 kVA BBU161B107035 1 24.3 9.6 5.6 3.1
    2 50.0 22.0 13.0 8.5
    3 79.5 37.0 22.5 15.5
    4 109.0 52.0 32.5 22.5
    BBU201B109035 1 39.0 14.2 8.2 6.0
    2 100.5 41.4 22.5 14.5
    3 164.4 72.5 42.0 27.5
    4 228.5 105.0 63.0 42.5
    8 kVA BBU201B109035 1 36.3 15.6 9.3 5.1
    2 71.0 27.0 14.5 9.6
    3 119.0 49.5 27.5 17.5
    4 167.5 73.5 42.5 27.5
    10 kVA BBU201B109035 1 30.2 11.9 6.2 3.7
    2 53.0 19.4 10.5 7.4
    3 91.0 36.0 19.5 12.5
    4 130.0 54.8 30.5 19.5

    15 kVA

    BBU201B109035 1 set (2 EBC) 39.3 16.8 10.0 6.8
    2 set (4 EBC) 90.5 41.1 25.0 17.2
    3 set (6 EBC) 143.1 67.4 41.9 29.2
    4 set (8 EBC) 196.1 94.3 59.7 42.1
    BBU161B107035 1 set (2 EBC) 16.4 7.1 4.0 2.3
    2 set (4 EBC) 39.3 17.6 10.6 7.4
    3 set (6 EBC) 63.5 29.5 17.9 12.5
    4 set (8 EBC) 88.2 41.9 25.8 18.2
    Li-ion battery :
    GES021B704035 + 099114191A
    1 set (2 EBC) 24.0 10.8 8.1 5.8
    20 kVA BBU201B109035 1 set (2 EBC) 27.5 11.5 6.8 4.4
    2 set (4 EBC) 65.1 28.7 17.2 11.8
    3 set (6 EBC) 104.4 47.8 29.2 20.2
    4 set (8 EBC) 144.3 67.7 42.1 29.3
    BBU161B107035 1 set (2 EBC) 11.6 4.8 2.3 1.3
    2 set (4 EBC) 28.3 12.3 7.4 4.6
    3 set (6 EBC) 46.4 20.7 12.5 8.6
    4 set (8 EBC) 65.1 29.8 18.2 12.5
    Li-ion battery :
    GES021B704035 + 099114191A
    1 set (2 EBC) 18.6 8.9 5.8 3.6